Analyzers

BD FACSymphony A5 Cell Analyzer (P01) - RTP, Room 2104
Biosafety: BSL2 and BSL2-Human specimen

  • Five lasers: Blue (488 nm), Green (561 nm), Red (637 nm), Violet (404 nm), and Ultraviolet (355 nm)

  • 31 parameters: Foward Scatter, Side Scatter, 6 fluorescent channels off the Blue, 5 fluorescent channels off the Green, 3 fluorescent channels off the Red, 8 fluorescent channels off the Violet, and 7 fluorescent channels off the Ultraviolet

  • High Throughput System: 96 and 384 well plate-based acquisition in addition to tubes

  • P01 configuration

 

BD LSRFortessa Cell Analyzer (F01) - RP, Room 105
Biosafety: BSL2

  • Four lasers: Blue (488 nm), Green (532 nm), Red (642 nm), and Violet (405 nm)

  • 20 parameters: Forward Scatter, Side Scatter, 2 fluorescent channels off the Blue, 5 fluorescent channels off the Green, 3 fluorescent channels off the Red, and 8 fluorescent channels off the Violet

  • F01 configuration

 

MilliporeSigma Muse Cell Analyzer (M01, M02) - RP, Room 105 and RTP, Room 2104
Biosafety: BSL2 and BSL2-Human specimen

IntelliCyt iQue Screener PLUS Cell Analyzer (Q01) - MSRBII, Room 4036
Biosafety: BSL2 and BSL2-Human specimen

  • Three lasers: Blue (488 nm), Red (642 nm), and Violet (405 nm)

  • 15 parameters: Forward Scatter, Side Scatter, 5 fluorescent channels off the Blue, 2 fluorescent channels off the Red, and 6 fluorescent channels off the Violet, that shares many of the same filters as our BD instruments, so will be readily adaptable to many panels designed for our other cytometers

  • PlateCrane EX High Throughput Robotic System: 96, 384 and 1536 well plate-based acquisition

  • Q01 configuration

BD LSRII Cell Analyzer (L01) - RP, Room 105
Biosafety: BSL2 and BSL2-Human specimen

 

MilliporeSigma Muse Cell Analyzer (M01, M02) - RP, Room 105 and RTP, Room 2104
Biosafety: BSL2 and BSL2-Human specimen

 

IntelliCyt iQue Screener PLUS Cell Analyzer (Q01) - MSRBII, Room 4036
Biosafety: BSL2 and BSL2-Human specimen

  • Three lasers: Blue (488 nm), Red (642 nm), and Violet (405 nm)

  • 15 parameters: Forward Scatter, Side Scatter, 5 fluorescent channels off the Blue, 2 fluorescent channels off the Red, and 6 fluorescent channels off the Violet, that shares many of the same filters as our BD instruments, so will be readily adaptable to many panels designed for our other cytometers

  • PlateCrane EX High Throughput Robotic System: 96, 384 and 1536 well plate-based acquisition

  • Q01 configuration

 

BD LSRII Cell Analyzer (L01) - RP, Room 105
Biosafety: BSL2 and BSL2-Human specimen

  • Four lasers: Blue (488 nm), Green (532 nm), Red (642 nm), and Violet (405 nm)

  • 20 parameters: Foward Scatter, Side Scatter, 2 fluorescent channels off the Blue, 5 fluorescent channels off the Green, 2 fluorescent channels off the Red, and 8 fluorescent channels off the Violet

  • High Throughput System: 96 and 384 well plate-based acquisition in addition to tubes

  • L01 configuration